All Product-GSK-N IPS 2000VA-GSK-N 2000VA

GSK-N Home IPS & UPS 2000 VA DC 24 V

SPECIFICATION OF GSK-N HOME IPS & UPS

GSK-N is an intelligent home  IPS. Now we will understand display indications on its front panel.

  • First, AC indicates AC is connected to AC Line.
  • Then CH indicates charging is going on. In this case, CH starts blinking. When the battery is fully charged then CH stops blinking and stands steadily.
  • Next in display, IPS indicates backup is ON.
  • When the load connected to the system is more than its rated load, then OL (overload) starts blinking. In this condition OL blinks eight times. After detecting the condition of overload, the system will automatically go off and then through this process, GSK-N  checks if the overload condition still there. If the overload condition is no there anymore, then the normal working of GSK-N restored. If then GSK-N repeats this process eight times. After retrying eight times, if the overload condition continues, then the system is permanently switched off and after to start the system the load needs to be reduced and power active switched needs to be reset.
  • The second case is when there is a shortcircuit in system output load, then the display shows OL. Afer detecting the condition of short circuit, system goes automatically off and then on. Through this process GSK-N checks if short circuit condition is not there anymore then normal working of GSk-N will be resumed. If the system is still short circuit condition, the GSK-N will repeat this process four times. After retrying four times, if the condition of short circuit continues, the system will go permanently off and after that to restart the system, we will have to remove short circuit and will have to reset power active switch. GSK-N is available in five ranges - 1200VA, 1500VA, 2000VA, 2500VA and 3000VA. 

  • At the back panel of GSK-N has fuse and cooling fan. There is an MCB for high ranges. 

  • After this we have battery low lb indication. There are two options of battery. Low cut in GSK-N 20V and 20.5V. The battery discharge at both these voltages. At around 20.5V battery low warning will start. In this condition lb starts blinking in display. This shows that the battery has been discharged. When the battery voltage becomes 20V and load stop running.